Smart computer board
The display lets your team choose how thick each cube forms, then the board runs the cycle. Thicker cubes for slow service, thinner cubes when you need ice fast.
A stainless steel cube ice machine for hotels, bars, cafés and seafood counters. Set the cube thickness on the computer board, let the automatic cleaning cycle run, and keep the bin full without putting a person on the machine.
Every choice inside the LZ series serves one outcome: a steady supply of clear cube ice, shift after shift, with the least possible attention from your team.
The display lets your team choose how thick each cube forms, then the board runs the cycle. Thicker cubes for slow service, thinner cubes when you need ice fast.
A high-efficiency copper-nickel evaporation plate pulls heat out quickly, so each cycle finishes sooner and every cube releases cleanly from the plate.
Water fill, freezing, harvest and restart happen on their own. Nobody has to stand at the machine — it is built to run safely with no specialist operator.
The refrigeration system uses imported branded components. That is the difference between a machine that runs for years and one that needs a technician every season.
The cabinet is foamed in a single pass with a fluorine-free process. Cold stays inside the bin, the shell stays dry, and the compressor has less work to do.
A stainless steel shell shrugs off steam, grease and daily wipe-downs. With the hot and cold sides fully isolated, the machine uses over 15% less water and electricity than ordinary machines.
Choose the output you need on your busiest day, then pick a bin size that carries you through the night. Both ranges share the same board, evaporator technology and stainless construction.
Fast freezing on a copper-nickel plate, a cabinet foamed as one sealed piece and a bin that holds temperature: that is what separates a cube that looks right on the bar from one that gives up in the glass. Thickness is your call, set on the board.
Ten models with the figures that decide an install: daily output, bin capacity, cooling method, power draw, refrigerant, net weight and cabinet size.
Tell us your busiest day and the voltage on site — we will point you at the right model.
| Model | Daily output | Ice storage | Cooling method | Voltage / current / power | Refrigerant | Net weight | Dimensions W × D × H (mm) |
|---|---|---|---|---|---|---|---|
| LZ-350 | 160 kg | 120 kg | Air / Water | 220V / 4.5A / 990W | R404A | 78 kg | 560 × 850 × 1600 |
| LZ-400 | 180 kg | 120 kg | Air / Water | 220V / 5A / 1100W | R404A | 87 kg | 560 × 850 × 1600 |
| LZ-500 | 227 kg | 200 kg | Air / Water | 220V / 5.5A / 1210W | R404A | 90 kg | 760 × 850 × 1600 |
| LZ-600 | 260 kg | 200 kg | Air / Water | 220V / 6.5A / 1430W | R404A | 101 kg | 760 × 850 × 1600 |
| LZ-700 | 318 kg | 200 kg | Air / Water | 220V / 8.3A / 1820W | R404A | 107 kg | 760 × 850 × 1600 |
| LZ-800 | 360 kg | 200 kg | Air / Water | 220V / 8.3A / 1600W | R404A | 111 kg | 760 × 850 × 1760 |
| LZ-1000 | 454 kg | 260 kg | Air / Water | 220V / 9A / 1800W | R404A | 117 kg | 760 × 850 × 1760 |
| LZ-1200 | 600 kg | 260 kg | Air / Water | 220V / 9.5A / 2090W | R404A | 129 kg | 760 × 850 × 1760 |
| LZ-1500 | 680 kg | 500 kg | Water | 220V / 11A / 2420W | R404A | 207 kg | 1227 × 950 × 1980 |
| LZ-2000 | 900 kg | 500 kg | Water | 380V / 5.8A / 3860W | R404A | 219 kg | 1227 × 950 × 2020 |
Dimensions are given as width × depth × height in millimetres. Output and storage figures follow the manufacturer’s published data for each model. Specifications may be revised without notice — the figures on your quotation are the ones that apply to your order.
All connections sit on the rear panel, so the machine can be pushed against a wall or dropped into a stainless run. Check these four points before the unit is placed.
Models LZ-350 to LZ-1500 run on 220V single phase; LZ-2000 needs 380V three phase. Size the circuit to the amps printed in the specification table.
An ice-making water inlet feeds the evaporator, and water-cooled models add a separate condenser water inlet beside it.
Ice-making water drain and condenser water drain run to waste, with the ice-release water outlet on the same rear face.
Air-cooled units reject heat into the room. Leave the condenser side open and level the cabinet on its legs before the first cycle.
From a 60-cover café to a seafood hall running 900 kg a day, the same machine design covers the whole range — you only change the model number and the bin size.
Water-cooled units reject heat through a water connection and suit small or hot rooms where air cooling struggles. Air-cooled units are simpler to place but need open space around the condenser. From LZ-350 to LZ-1200 both options are available; LZ-1500 and LZ-2000 are water-cooled only.
Start from your busiest day rather than an average one. Add the ice you serve across peak hours to what you want left in the bin overnight, then pick the next model up. Bins hold 120 kg to 500 kg depending on model, so the storage figure matters as much as the daily output.
Yes. Thickness is selected on the computer board, so one machine can run thicker cubes for drinks service or thinner cubes for display cases and rapid chilling.
Most models run on 220V single phase between 4.5A and 11A. LZ-2000 is the exception at 380V three phase, 5.8A. Wattage for every model is listed in the specification table above.
The board includes automatic cleaning functions, and the stainless shell wipes down without special care. Day to day your team only needs to keep the bin clean and check the rear water connections.
Send the model you are considering, the voltage on site and your delivery country. If you are unsure between two models, describe your daily volume and we will match one for you.